ANTU
|
CAS
86-88-4
|
C10H7NHC(NH2)S
|
RTECS
YT9275000
|
Synonyms & Trade Names
alpha-Naphthyl thiocarbamide, 1-Naphthyl thiourea, alpha-Naphthyl thiourea
|
DOT ID & Guide
1651 / 153
|
Exposure Limits
|
NIOSH REL: TWA 0.3 mg/m3
|
OSHA PEL: TWA 0.3 mg/m3
|
IDLH
100 mg/m3
See: 86884
|
Conversion
|
Physical Description
White crystalline or gray, odorless powder. [rodenticide]
|
MW: 202.3
|
BP: Decomposes
|
MLT: 388°F
|
Sol: 0.06%
|
VP: Low
|
IP: ?
|
|
Sp.Gr: ?
|
Fl.P: NA
|
UEL: NA
|
LEL: NA
|
|
Noncombustible Solid
|
Incompatibilities & Reactivities
Strong oxidizers, silver nitrate
|
Measurement Methods
NIOSH S276 (II-5)
See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection)
Skin: No recommendation
Eyes: No recommendation
Wash skin: No recommendation
Remove: No recommendation
Change: Daily
|
First Aid (See procedures)
Eye: Irrigate immediately
Skin: Soap wash promptly
Breathing: Respiratory support
Swallow: Medical attention immediately
|
Respirator Recommendations
NIOSH/OSHA
Up to 3 mg/m3: (APF = 10) Any air-purifying half-mask respirator with organic vapor cartridge(s) in combination with an N95, R95, or P95 filter. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters. (APF = 10) Any supplied-air respirator
Up to 7.5 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode (APF = 25) Any powered air-purifying respirator with an organic vapor cartridge in combination with a high-efficiency particulate filter.
Up to 15 mg/m3: (APF = 50) Any air-purifying full-facepiece respirator equipped with organic vapor cartridge(s) in combination with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s) in combination with a high-efficiency particulate filter (APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece
Up to 100 mg/m3: (APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus
Important additional information about respirator selection
|
Exposure Routes
inhalation, ingestion
|
Symptoms
After ingestion of large doses: vomiting, dyspnea (breathing difficulty), cyanosis, coarse pulmonary rales; liver damage
|
Target Organs
respiratory system, blood, liver
|
See also: INTRODUCTION
See ICSC CARD: 0973 |