Chlorodiphenyl (42% chlorine)
|
CAS
53469-21-9
|
C6H4ClC6H3Cl2 (approx)
|
RTECS
TQ1356000
|
Synonyms & Trade Names
Aroclor® 1242, PCB, Polychlorinated biphenyl
|
DOT ID & Guide
2315 / 171
|
Exposure Limits
|
NIOSH REL*: Ca TWA 0.001 mg/m3 See Appendix A [*Note: The REL also applies to other PCBs.]
|
OSHA PEL: TWA 1 mg/m3 [skin]
|
IDLH
Ca [5 mg/m3]
See: 53469219
|
Conversion
|
Physical Description
Colorless to light-colored, viscous liquid with a mild, hydrocarbon odor.
|
MW: 258 (approx)
|
BP: 617-691°F
|
FRZ: -2°F
|
Sol: Insoluble
|
VP: 0.001 mmHg
|
IP: ?
|
|
Sp.Gr(77°F): 1.39
|
Fl.P: NA
|
UEL: NA
|
LEL: NA
|
|
Nonflammable Liquid, but exposure in a fire results in the formation of a black soot containing PCBs, polychlorinated dibenzofurans & chlorinated dibenzo-p-dioxins.
|
Incompatibilities & Reactivities
Strong oxidizers
|
Measurement Methods
NIOSH 5503; OSHA PV2089
See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection)
Skin: Prevent skin contact
Eyes: Prevent eye contact
Wash skin: When contaminated
Remove: When wet or contaminated
Change: Daily
Provide: Eyewash, Quick drench
|
First Aid (See procedures)
Eye: Irrigate immediately
Skin: Soap wash immediately
Breathing: Respiratory support
Swallow: Medical attention immediately
|
Respirator Recommendations
NIOSH
At concentrations above the NIOSH REL, or where there is no REL, at any detectable concentration: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus
Important additional information about respirator selection
|
Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contact
|
Symptoms
Irritation eyes; chloracne; liver damage; reproductive effects; [potential occupational carcinogen]
|
Target Organs
Skin, eyes, liver, reproductive system
Cancer Site
[in animals: tumors of the pituitary gland & liver, leukemia]
|
See also: INTRODUCTION
See MEDICAL TESTS: 0175
|