Dichlorotetrafluoroethane
|
CAS
76-14-2
|
CClF2CClF2
|
RTECS
KI1101000
|
Synonyms & Trade Names
1,2-Dichlorotetrafluoroethane; Freon® 114; Genetron® 114; Halon® 242; Refrigerant 114
|
DOT ID & Guide
1958 / 126
|
Exposure Limits
|
NIOSH REL: TWA 1000 ppm (7000 mg/m3)
|
OSHA PEL: TWA 1000 ppm (7000 mg/m3)
|
IDLH
15,000 ppm
See: 76142
|
Conversion
1 ppm = 6.99 mg/m3
|
Physical Description
Colorless gas with a faint, ether-like odor at high concentrations. [Note: A liquid below 38°F. Shipped as a liquefied compressed gas.]
|
MW: 170.9
|
BP: 38°F
|
FRZ: -137°F
|
Sol: 0.01%
|
VP(70°F): 1.9 atm
|
IP: 12.20 eV
|
RGasD: 5.93
|
|
Fl.P: NA
|
UEL: NA
|
LEL: NA
|
|
Nonflammable Gas
|
Incompatibilities & Reactivities
Chemically-active metals such as sodium, potassium, calcium, powdered aluminum, zinc & magnesium; acids; acid fumes
|
Measurement Methods
NIOSH 1018
See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection)
Skin: Frostbite
Eyes: Frostbite
Wash skin: No recommendation
Remove: No recommendation
Change: No recommendation
Provide: Frostbite wash
|
First Aid (See procedures)
Eye: Frostbite
Skin: Frostbite
Breathing: Respiratory support
|
Respirator Recommendations
NIOSH/OSHA
Up to 10,000 ppm: (APF = 10) Any supplied-air respirator
Up to 15,000 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece
Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure- demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister/Any appropriate escape-type, self-contained breathing apparatus
Important additional information about respirator selection
|
Exposure Routes
inhalation, skin and/or eye contact (liquid)
|
Symptoms
Irritation respiratory system; asphyxia; cardiac arrhythmias, cardiac arrest; liquid: frostbite
|
Target Organs
respiratory system, cardiovascular system
|
See also: INTRODUCTION See ICSC CARD: 0649
|