Ethylenediamine
|
CAS
107-15-3
|
NH2CH2CH2NH2
|
RTECS
KH8575000
|
Synonyms & Trade Names
1,2-Diaminoethane; 1,2-Ethanediamine; Ethylenediamine (anhydrous)
|
DOT ID & Guide
1604 / 132
|
Exposure Limits
|
NIOSH REL: TWA 10 ppm (25 mg/m3)
|
OSHA PEL: TWA 10 ppm (25 mg/m3)
|
IDLH
1000 ppm
See: 107153
|
Conversion
1 ppm = 2.46 mg/m3
|
Physical Description
Colorless, viscous liquid with an ammonia-like odor. [fungicide] [Note: A solid below 47°F.]
|
MW: 60.1
|
BP: 241°F
|
FRZ: 47°F
|
Sol: Miscible
|
VP: 11 mmHg
|
IP: 8.60 eV
|
|
Sp.Gr: 0.91
|
Fl.P: 93°F
|
UEL(212°F): 12%
|
LEL(212°F): 2.5%
|
|
Class IC Flammable Liquid: Fl.P. at or above 73°F and below 100°F.
|
Incompatibilities & Reactivities
Strong acids & oxidizers, carbon tetrachloride & other chlorinated organic compounds, carbon disulfide [Note: Corrosive to metals.]
|
Measurement Methods
NIOSH 2540; OSHA 60
See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection)
Skin: Prevent skin contact
Eyes: Prevent eye contact
Wash skin: When contaminated/Daily
Remove: When wet (flammable)
Change: No recommendation
Provide: Eyewash (>5%), Quick drench
|
First Aid (See procedures)
Eye: Irrigate immediately
Skin: Water flush immediately
Breathing: Respiratory support
Swallow: Medical attention immediately
|
Respirator Recommendations
NIOSH/OSHA
Up to 250 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode£ (APF = 25) Any powered, air-purifying respirator with cartridge(s) providing protection against the compound of concern£
Up to 500 ppm: (APF = 50) Any chemical cartridge respirator with a full facepiece and cartridge(s) providing protection against the compound of concern (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted canister providing protection against the compound of concern (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and cartridge(s) providing protection against the compound of concern£ (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece
Up to 1000 ppm: (APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted canister providing protection against the compound of concern/Any appropriate escape-type, self-contained breathing apparatus
Important additional information about respirator selection
|
Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contact
|
Symptoms
Irritation nose, respiratory system; sensitization dermatitis; asthma; liver, kidney damage
|
Target Organs
Skin, respiratory system, liver, kidneys
|
See also: INTRODUCTION
See ICSC CARD: 0269 |