Ferrovanadium dust
|
CAS
12604-58-9
|
FeV
|
RTECS
LK2900000
|
Synonyms & Trade Names
Ferrovanadium
|
DOT ID & Guide
|
Exposure Limits
|
NIOSH REL*: TWA 1 mg/m3 ST 3 mg/m3 [*Note: The REL also applies to Vanadium metal and Vanadium carbide.]
|
OSHA PEL†: TWA 1 mg/m3
|
IDLH
500 mg/m3
See: 12604589
|
Conversion
|
Physical Description
Dark, odorless particulate dispersed in air. [Note: Ferrovanadium metal is an alloy usually containing 50-80% vanadium.]
|
MW: 106.8
|
BP: ?
|
MLT: 2696-2768°F
|
Sol: Insoluble
|
VP: 0 mmHg (approx)
|
IP: NA
|
|
Sp.Gr: ?
|
Fl.P: NA
|
UEL: NA
|
LEL: NA
|
MEC: 1.3 g/m3
|
Metal: Noncombustible Solid, but dust may be an explosion hazard.
|
Incompatibilities & Reactivities
Strong oxidizers
|
Measurement Methods
OSHA ID121, ID125G
See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection)
Skin: No recommendation
Eyes: No recommendation
Wash skin: No recommendation
Remove: No recommendation
Change: No recommendation
|
First Aid (See procedures)
Eye: Irrigate immediately
Breathing: Respiratory support
|
Respirator Recommendations
NIOSH/OSHA
Up to 5 mg/m3: (APF = 5) Any quarter-mask respirator. Click here for information on selection of N, R, or P filters.*
Up to 10 mg/m3: (APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters.* (APF = 10) Any supplied-air respirator*
Up to 25 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode* (APF = 25) Any powered air-purifying respirator with a high-efficiency particulate filter.*
Up to 50 mg/m3: (APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode* (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter* (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece
Up to 500 mg/m3: (APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape: (APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus
Important additional information about respirator selection
|
Exposure Routes
inhalation, skin and/or eye contact
|
Symptoms
Irritation eyes, respiratory system; in animals: bronchitis, pneumonitis
|
Target Organs
Eyes, respiratory system
|
See also: INTRODUCTION