Tetramethyl lead (as Pb)
|
CAS
75-74-1
|
Pb(CH3)4
|
RTECS
TP4725000
|
Synonyms & Trade Names
Lead tetramethyl, Tetramethylplumbane, TML
|
DOT ID & Guide
|
Exposure Limits
|
NIOSH REL: TWA 0.075 mg/m3 [skin]
|
OSHA PEL: TWA 0.075 mg/m3 [skin]
|
IDLH
40 mg/m3 (as Pb)
See: 75741
|
Conversion
|
Physical Description
Colorless liquid (unless dyed red, orange, or blue) with a fruity odor. [Note: Main usage is in anti-knock additives for gasoline.]
|
MW: 267.3
|
BP: 212°F (Decomposes)
|
FRZ: -15°F
|
Sol: 0.002%
|
VP: 23 mmHg
|
IP: 8.50 eV
|
|
Sp.Gr: 2.00
|
Fl.P: 100°F
|
UEL: ?
|
LEL: ?
|
|
Class II Combustible Liquid: Fl.P. at or above 100°F and below 140°F.
|
Incompatibilities & Reactivities
Strong oxidizers such as sulfuryl chloride or potassium permanganate
|
Measurement Methods
NIOSH 2534
See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection)
Skin: Prevent skin contact (>0.1%)
Eyes: Prevent eye contact
Wash skin: When contaminated (>0.1%)
Remove: When wet or contaminated (>0.1%)
Change: Daily
Provide: Quick drench (>0.1%)
|
First Aid (See procedures)
Eye: Irrigate immediately
Skin: Soap wash immediately
Breathing: Respiratory support
Swallow: Medical attention immediately
|
Respirator Recommendations
NIOSH/OSHA
Up to 0.75 mg/m3: (APF = 10) Any supplied-air respirator
Up to 1.875 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode
Up to 3.75 mg/m3: (APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece
Up to 40 mg/m3: (APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure- demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister/Any appropriate escape-type, self-contained breathing apparatus
Important additional information about respirator selection
|
Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contact
|
Symptoms
Insomnia, bad dreams, restlessness, anxious; hypotension; nausea, anorexia; delirium, mania, convulsions; coma
|
Target Organs
central nervous system, cardiovascular system, kidneys
|
See also: INTRODUCTION
See ICSC CARD: 0200 See MEDICAL TESTS: 0225
|